Recalls and alerts more than 4 years old are automatically archived. While this information can still be accessed in the database, it has not been altered or updated since it was archived. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats by contacting us.
INVIRASE (saquinavir mesylate) - Need for electrocardiogram monitoring in patients - For Health Professionals
- Starting date:
- October 27, 2010
- Posting date:
- November 2, 2010
- Type of communication:
- Dear Healthcare Professional Letter
- Subcategory:
- Drugs
- Source of recall:
- Health Canada
- Audience:
- Healthcare Professionals
- Identification number:
- RA-170002303
This is duplicated text of a letter from Hoffmann-La Roche Limited.
Contact the company for a copy of any references, attachments or enclosures.
Notice about Health Canada advisories
Health Canada Endorsed Important Safety Information on INVIRASE (saquinavir mesylate)
October 27, 2010
Dear Health Care Professional,
Subject: Updated Prescribing Information for INVIRASE® (saquinavir mesylate) Regarding QT/PR Interval Prolongation and the Need for ECG Monitoring in the Treatment of HIV-infected Patients with ritonavir-boosted INVIRASE®
Hoffmann-La Roche Limited, in consultation with Health Canada, would like to inform healthcare professionals of updates to the Canadian Product Monograph (CPM) for INVIRASE. Additional cautionary language has been provided in the CPM to strengthen the warnings regarding QT/PR interval prolongation and to stress the need for electrocardiogram (ECG) monitoring in the treatment of HIV-infected patients with ritonavir-boosted INVIRASE.
INVIRASE is authorized for the treatment of HIV-1 infected adult patients. INVIRASE should only be given in combination with ritonavir and other antiretroviral products.
- An ECG should be completed prior to initiation of ritonavir-boosted INVIRASE;
- Patients with a QT interval greater than 450 msec should NOT use ritonavir-boosted INVIRASE;
- An on-treatment ECG is recommended after 3-4 days of treatment. If a patient's QT interval is greater than 20 msec above pre-treatment values, or greater than 480 msec, then ritonavir-boosted INVIRASE should be discontinued;
- Caution is advised when co-administering ritonavir-boosted INVIRASE and other therapies that may increase the QT interval. ECG monitoring should be performed in this patient population (see WARNINGS AND PRECAUTIONS, section, below).
The updated CPM can be found on the Roche Canada Web site or can be accessed by performing a search in Health Canada's Drug Product Database. The main updates to the CPM include the following information:
WARNINGS AND PRECAUTIONS, Cardiovascular - Cardiac conduction and repolarisation abnormalities:
Patients initiating therapy with ritonavir-boosted INVIRASE: An ECG should be performed prior to initiation of treatment. Patients with a QT interval > 450 msec should not use ritonavir-boosted INVIRASE. For patients with a QT interval < 450 msec, an on-treatment ECG is suggested after approximately 3 to 4 days of therapy. Patients with a QT interval > 480 msec or prolongation over pre-treatment by > 20 msec on their on-treatment ECG should discontinue ritonavir-boosted INVIRASE.
Patients stable on ritonavir-boosted INVIRASE and requiring concomitant medication with potential to increase the QT interval or patients on medication with potential to increase the QT interval and requiring concomitant ritonavir-boosted INVIRASE where no alternative therapy is available and the benefits outweigh the risks: An ECG should be performed prior to initiation of the concomitant therapy, and patients with a QT interval > 450 msec should not initiate the concomitant therapy (see DRUG INTERACTIONS and CONTRAINDICATIONS). If baseline QT interval < 450 msec, an on-treatment ECG should be performed. For patients demonstrating a subsequent increase in QT interval to > 480 msec or increase by > 20 msec after commencing concomitant therapy, the physician should use best clinical judgment to discontinue either ritonavir-boosted INVIRASE or the concomitant therapy or both.
Ritonavir-boosted INVIRASE at a dose of 2000 mg once daily with ritonavir 100 mg once daily has not been studied with regard to the risk of QT prolongation and is not recommended.
Hoffman-La Roche Limited continues to monitor adverse events of QT and PR interval prolongation associated with INVIRASE and ritonavir-boosted INVIRASE and is committed to providing healthcare professionals with the most current information for its products.
Managing marketed health product-related adverse reactions depends on health care professionals and consumers reporting them. Reporting rates determined on the basis of spontaneously reported post-marketing adverse reactions are generally presumed to underestimate the risks associated with health product treatments. Any case of serious prolongations of QT and PR intervals or other serious or unexpected adverse reactions in patients receiving INVIRASE should be reported to Hoffmann-La Roche Limited or Health Canada at the following addresses:
Hoffmann-La Roche Limited
Drug Safety Department
2455 Meadowpine Boulevard
Mississauga, Ontario, L5N 6L7
Or call toll free at: 1-888-762-4388
Or fax at: 905-542-5864
Or email to: Mississauga.drug_safety@roche.com
You can report any suspected adverse reactions associated with the use of health products to the Canada Vigilance Program by one of the following three ways:
- Report online at MedEffect™ Canada Web site
- Call toll-free at 1-866-234-2345
-
Complete a Reporting Form and:
- Fax toll-free to 1-866-678-6789, or
-
Mail to: Canada Vigilance Program
- Health Canada
- Postal Locator 0701E
- Ottawa, Ontario K1A 0K9
The Reporting Forms, postage paid labels, and Guidelines can be found on the MedEffectTM Canada Web site in the Adverse Reaction Reporting section. The Reporting Form is also in the Canadian Compendium of Pharmaceuticals and Specialties.
For other health product inquiries related to this communication, please contact Health Canada at:
Marketed Health Products Directorate (MHPD)
E-mail: MHPD_DPSC@hc-sc.gc.ca
Telephone: 613-954-6522
Fax: 613-952-7738
To change your mailing address or fax number, contact the Market Authorization Holder (Industry).
Should you have any questions or require additional information regarding the use of INVIRASE, please contact the Drug Information Department at Hoffmann-La Roche Limited at 1-888-762-4388 from 8:30 a.m. to 4:30 p.m. Monday to Friday Eastern Standard Time.
Sincerely,
original signed by
Lorenzo Biondi,
Vice President, Medical and Regulatory Affairs
Hoffmann-La Roche Limited
- Date modified: